RE - RT - RS - Thermal Containers

GP - General Purpose Containers without ventilation

G0 - Openings at one or both ends

G1 - Passive vents at upper part of cargo space

G2 - Openings at one or both ends + full openings on one or both sides

G3 - Openings at one or both ends + partial openings on one or both sides


VH - General Purpose Containers with ventilation

V0 - Non-mechanical,vents at lower and upper parts of cargo space

V2 - Mechanical ventilation system located internally

V4 - Mechanical ventilation system located externally

R0 - Mechanically refrigirated

R1 - Mechanically refrigirated and heated

R2 - Self powered mechanically refrigirated

R3 - Self powered mechanically refrigirated and heated


HR - HI - Thermal Containers

H0 - Refrigirated or heated with removable equipment located externally; heat transfer coefficient K= 0.4W / M2.K

H1 - Refrigirated or heated with removable equipment located internally

H2 - Refrigirated or heated with removable equipment located externally; heat transfer coefficient K= 0.7W / M2.K

H5 - Insulated. Heat transfer coefficient K= 0.4W / M2.K

H6 - Insulated. Heat transfer coefficient K= 0.7W / M2.K


UT - Open Top Containers

U0 - Openings at one or both ends

U1 - Idem + removable top members in end frames

U2 - Openings at one or both ends + openings at one or both sides

U3 - Idem + removable top members in end frames

U4 - Openings at one or both ends + partial on one and full at other side

U5 - Complete, fixed side and end walls (no doors)


TN - TD - TG - Tank

T0 - Non dangerous liquids, minimum pressure 0.45 bar

T1 - Non dangerous liquids, minimum pressure 1.50 bar

T2 - Non dangerous liquids, minimum pressure 2.65 bar

T3 - Dangerous liquids, minimum pressure 1.50 bar

T4 - Dangerous liquids, minimum pressure 2.65 bar

T5 - Dangerous liquids, minimum pressure 4.00 bar

T6 - Dangerous liquids, minimum pressure 6.00 bar

T7 - Gases, minimum pressure 9.10 bar

T8 - Gases, minimum pressure 22.00 bar

T9 - Gases, minimum pressure to be decided


BU - BK - Dry Bulk Containers

B0 - Closed

B1 - Airtight

B3 - Horizontal discharge, test pressure 1.50 bar

B4 - Horizontal discharge, test pressure 2.65 bar

B5 - Tipping discharge, test pressure 1.50 bar

B6 - Tipping discharge, test pressure 2.65 bar


PL - PF - PC - PS - Platform Containers

P0 - Plain platform

P1 - Two complete and fixed ends

P2 - Fixed posts, either free-standing or with removable top member

P3 - Folding complete end structure

P4 - Folding posts, either free-standing or with removable top member

P5 - Open top, open ends (skeletal)


SN - Named Cargo Containers

S0 - Livestock carrier

S1 - Automobile carrier

S2 - Live fish carrier

На контейнере также наносится: на дверях — максимальная масса брутто (MGW) и собственная масса (TARE) в килограммах (kg) и фунтах (1b). При этом, например, для контейнеров типоразмера ICC может указываться максимальная масса брутто, равная 24 384 кг, а не 24 000 кг. Это происходит из-за более точного перерасчета фунтов в килограммы и не содержит противоречия или указаний на допусти­мый перегруз.