RE - RT - RS - Thermal Containers
GP - General Purpose Containers without ventilation
G0 - Openings at one or both ends
G1 - Passive vents at upper part of cargo space
G2 - Openings at one or both ends + full openings on one or both sides
G3 - Openings at one or both ends + partial openings on one or both sides
VH - General Purpose Containers with ventilation
V0 - Non-mechanical,vents at lower and upper parts of cargo space
V2 - Mechanical ventilation system located internally
V4 - Mechanical ventilation system located externally
R0 - Mechanically refrigirated
R1 - Mechanically refrigirated and heated
R2 - Self powered mechanically refrigirated
R3 - Self powered mechanically refrigirated and heated
HR - HI - Thermal Containers
H0 - Refrigirated or heated with removable equipment located externally; heat transfer coefficient K= 0.4W / M2.K
H1 - Refrigirated or heated with removable equipment located internally
H2 - Refrigirated or heated with removable equipment located externally; heat transfer coefficient K= 0.7W / M2.K
H5 - Insulated. Heat transfer coefficient K= 0.4W / M2.K
H6 - Insulated. Heat transfer coefficient K= 0.7W / M2.K
UT - Open Top Containers
U0 - Openings at one or both ends
U1 - Idem + removable top members in end frames
U2 - Openings at one or both ends + openings at one or both sides
U3 - Idem + removable top members in end frames
U4 - Openings at one or both ends + partial on one and full at other side
U5 - Complete, fixed side and end walls (no doors)
TN - TD - TG - Tank
T0 - Non dangerous liquids, minimum pressure 0.45 bar
T1 - Non dangerous liquids, minimum pressure 1.50 bar
T2 - Non dangerous liquids, minimum pressure 2.65 bar
T3 - Dangerous liquids, minimum pressure 1.50 bar
|
|
T4 - Dangerous liquids, minimum pressure 2.65 bar
T5 - Dangerous liquids, minimum pressure 4.00 bar
T6 - Dangerous liquids, minimum pressure 6.00 bar
T7 - Gases, minimum pressure 9.10 bar
T8 - Gases, minimum pressure 22.00 bar
T9 - Gases, minimum pressure to be decided
BU - BK - Dry Bulk Containers
B0 - Closed
B1 - Airtight
B3 - Horizontal discharge, test pressure 1.50 bar
B4 - Horizontal discharge, test pressure 2.65 bar
B5 - Tipping discharge, test pressure 1.50 bar
B6 - Tipping discharge, test pressure 2.65 bar
PL - PF - PC - PS - Platform Containers
P0 - Plain platform
P1 - Two complete and fixed ends
P2 - Fixed posts, either free-standing or with removable top member
P3 - Folding complete end structure
P4 - Folding posts, either free-standing or with removable top member
P5 - Open top, open ends (skeletal)
SN - Named Cargo Containers
S0 - Livestock carrier
S1 - Automobile carrier
S2 - Live fish carrier
На контейнере также наносится: на дверях — максимальная масса брутто (MGW) и собственная масса (TARE) в килограммах (kg) и фунтах (1b). При этом, например, для контейнеров типоразмера ICC может указываться максимальная масса брутто, равная 24 384 кг, а не 24 000 кг. Это происходит из-за более точного перерасчета фунтов в килограммы и не содержит противоречия или указаний на допустимый перегруз.
На боковых стенках контейнера указывается срок (месяц и год) очередного капитального ремонта.